Cabling EX4200 or EX4300 Series Switches Virtual Chassis for a QFX3000-G QFabric
System Control Plane
Copyright © 2018, Juniper Networks, Inc.
Follow instructions for connecting power as appropriate for your site:
6.
Connecting AC Power to an EX4300 Switch
Connecting DC Power to an EX4300 Switch
Register your product by following instructions in Registering Products—Mandatory for
7.
Validating SLAs.
Perform initial configuration of the switch by following the instructions in Connecting
8.
and Configuring an EX Series Switch (CLI Procedure) or Connecting and Configuring an
EX Series Switch (J-Web Procedure).
Set the switch's management options by following the instructions in:
9.
Connecting a Device to a Network for Out-of-Band Management
Connecting a Device to a Management Console by Using an RJ-45 Connector
Connecting an EX Series Switch to a Management Console by Using the Mini-USB
Type-B Console Port
Rack Requirements
Cabinet Requirements
Clearance Requirements for Airflow and Hardware Maintenance for EX4300 Switches
on page 251
A QFX3000-G QFabric system control plane and management network is formed by
connecting the QFX Series devices in your network to two Virtual Chassis. In both a
copper-based control plane and a fiber-based control plane, each Virtual Chassis is
comprised of four EX4200-48T Series switches or EX4300-48P Series switches in a ring
topology. You cannot mix the EX4200 with EX4300 Series switches in the same virtual
chassis or in the same QFabric system.
The EX4200 has two dedicated 64-Gigabit Virtual Chassis Ports (VCP) that are used to
cable the Virtual Chassis. These two ports are located on the rear, or field-replaceable
unit (FRU) end of the EX4200. Likewise, the EX4300 has four 40-Gigabit Ethernet quad
small form-factor pluggable plus (QSFP+) VCPs on the FRU end of the chassis.
Before you cable the four EX Series switches in a ring topology, install your EX4200 or
EX4300 switches in a rack or cabinet. See
on page 491
or
"Installing and Connecting an EX4300 Switch" on page
Use
Figure 208 on page
494,
Figure 211 on page 496
as guides for cabling a control plane Virtual Chassis.
Chapter 34: Installing the Control Plane Network
"Installing and Connecting an EX4200 Switch"
Figure 209 on page
494,
Figure 210 on page
492.
495, and
493