Powering On a QFX3008-I Interconnect Device
Copyright © 2018, Juniper Networks, Inc.
Verify that the power cable connections are correct.
8.
Replace the cover on the wiring compartment, and using a number 1 Phillips (+)
9.
screwdriver, tighten the four screws.
Repeat Step
3
through Step
10.
Powering On a QFX3008-I Interconnect Device on page 425
Wiring Tray in a QFX3008-I Interconnect Device on page 58
Wiring Tray LEDs on a QFX3008-I Interconnect Device on page 735
Before you power on the QFX3008-I Interconnect device, ensure that:
You understand how to protect the device from electrostatic damage. See
of Electrostatic Discharge Damage" on page
You have connected the QFX3008-I Interconnect device to the QFabric system control
plane and management network. See
Overview" on page
373.
Ensure that you have the following parts and tools available to power on the device:
An electrostatic discharge (ESD) grounding strap.
To power on the device:
Attach the ESD grounding strap to your bare wrist and connect the strap to the ESD
1.
point on the chassis.
Ensure that the power supplies are fully inserted in the chassis.
2.
Ensure that the source power cords are installed correctly for each wiring tray, and
3.
the wiring trays are fully inserted in the chassis.
Switch on the site circuit breakers.
4.
Set a wiring tray's switch to the ON (|) position. Observe the power supply and wiring
5.
tray faceplate LEDs. If the wiring trays are installed correctly and functioning normally,
the LEDs light green and remain constantly lit.
Repeat Step
5
for the second wiring tray installed in the device.
6.
Chapter 29: Installing a QFX3008-I Interconnect Device
9
for the other wiring tray.