Figure 272: Removing A Power Supply From A 1 U Qfx5100 Device; Figure 273: Removing A Power Supply From A Qfx5100-96S Device - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Installing a Power Supply in a QFX5100 Device
668

Figure 272: Removing a Power Supply from a 1 U QFX5100 Device

Figure 273: Removing a Power Supply from a QFX5100-96S Device

AC Power Supply for a QFX5100 Device on page 94
Connecting AC Power to a QFX5100 Device on page 443
Connecting DC Power to a QFX5100 Device on page 446
Installing a Power Supply in a QFX5100 Device on page 668
The QFX5100 is shipped from the factory with two power supplies. Each power supply
is a hot-removable and hot-insertable field-replaceable unit (FRU) when the second
power supply is installed and running. You can install replacement power supplies in the
two slots next to the fan modules without powering off the switch or disrupting the
switching function.
Before you install a power supply in a QFX5100 device, ensure that you have taken the
necessary precautions to prevent electrostatic discharge (ESD) damage (see
"Prevention of Electrostatic Discharge Damage" on page
Ensure that the airflow direction of the power supply is the same as the chassis. Labels
on the power supply handle indicate the direction of airflow. See
Airflow in a QFX5100 Device" on page 88
To install a power supply in a QFX5100 device (see
Figure 275 on page
669):
360).
"Cooling System and
for more information.
Figure 274 on page 669
Copyright © 2018, Juniper Networks, Inc.