Table 245: Qfx3008-I Chassis Alarm Messages - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

Table 245: QFX3008-I Chassis Alarm Messages

Component
Alarm Type
Control Board and
Major (red)
Routing Engine
NOTE:
The Routing
Engine is located on
the Control Board
Minor (yellow)
Copyright © 2018, Juniper Networks, Inc.
CLI Message
slot-number CB Not online
Backup RE Active
Loss of communication with Backup RE
Mixed Master and Backup RE types
CB slot-number CPE Connectivity down
CB slot-number Removed
Chapter 59: Alarms and System Log Messages
Recommended Action
Replace the Control Board and report the
failure to customer support
No action is required if the backup
Routing Engine was intentionally made
active.
If the master Routing Engine failed,
replace it.
Replace the failed Control Board.
Both Routing Engines must be the same
model number.
Replace one of the Control Boards.
Indicates that all links from the control
board to the QFabric system control
plane network are down.
Check connectivity between the
QFX3008-I Interconnect device and the
EX4200 switches.
Indicates the chassis was powered on
with both Control Boards installed, but
one has been removed. The chassis can
continue to operate without the Control
Board, but airflow can be affected by the
empty slot. Replace the missing Control
Board as soon as possible.
899

Advertisement

Table of Contents
loading

Table of Contents