Table 246: QFX3600 and QFX3600-I Chassis Alarm Messages (continued)
Component
Alarm Type
Temperature
Major (red)
sensors
Minor (yellow)
Related
Documentation
Chassis Alarm Messages on a QFX3500 Device
Copyright © 2018, Juniper Networks, Inc.
CLI Message
sensor-location Temp Sensor Fail
sensor-location Temp Sensor Too Hot
sensor-location Temp Sensor Too Warm
Chassis Status LEDs in the QFX3600 and QFX3600-I Device on page 749
Configuring the Junos OS to Determine Conditions That Trigger Alarms on Different
Interface Types
alarm
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms
are preset and cannot be modified.
The chassis alarm message count is displayed on the LCD panel on the front of the device.
To view the chassis alarm message text remotely, use the
Chassis alarms on QFX3500 devices have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of
the conditions described in
immediate action.
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left
unchecked, might cause an interruption in service or degradation in performance. A
yellow alarm condition requires monitoring or maintenance.
Table 247 on page 906
describes the chassis alarm messages on QFX3500 devices.
Chapter 59: Alarms and System Log Messages
Recommended Action
Check the system log for the following
message and report it to customer
support:
Temp sensor sensor-number failed
sensor-number may range from 1 through
10.
Check environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) are not
affecting the temperature sensor. If the
condition persists, the device may shut
down.
For information only. Check
environmental conditions and alarms on
other devices. Ensure that environmental
factors (such as hot air blowing around
the equipment) are not affecting the
temperature sensor.
Table 247 on page
906. A red alarm condition requires
, where
CLI command.