Figure 241: Installing An Ac Power Supply In A Qfx3008-I Interconnect; Device - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Removing a Wiring Tray from a QFX3008-I Interconnect Device
608
Figure 241: Installing an AC Power Supply in a QFX3008-I Interconnect Device
Tighten
thumbscrew
AC Power Supply in a QFX3008-I Interconnect Device on page 56
Removing an AC Power Supply from a QFX3008-I Interconnect Device on page 605
The wiring tray in a QFX3008-I Interconnect device is a hot-insertable and hot-removable
field-replaceable unit (FRU). Two wiring trays are installed in the rear of the chassis.
Before you remove a wiring tray from the device, ensure that you understand how to
prevent ESD damage. See
Ensure that you have the following parts and tools available to remove a wiring tray from
a QFX3008-I Interconnect device:
Electrostatic discharge (ESD) grounding strap
Phillips (+) screwdriver, number 1
Replacement wiring tray
CAUTION:
Do not leave the wiring tray slot empty while the device is
operational. Replace the wiring tray promptly.