Related
Documentation
Installing a Fan Module in a QFX5100 Device
Copyright © 2018, Juniper Networks, Inc.
Figure 283: Removing a Fan Module from a 1 U QFX5100 Device
Figure 284: Removing a Fan Module from a 2 U QFX5100-96S Device
NOTE:
When a fan module is removed, the CLI message Fan/Blower is Absent
is logged in the system log, and the system raises a minor alarm.
Cooling System and Airflow in a QFX5100 Device on page 88
Field-Replaceable Units in a QFX5100 Device on page 75
Management Panel of a QFX5100 Device on page 85
Installing a Fan Module in a QFX5100 Device on page 677
The fan modules in a QFX5100 device are hot-removable and hot-insertable
field-replaceable units (FRUs): you can remove and replace them without powering off
the switch or disrupting switch functions.
CAUTION:
Replace a failed fan module with a new fan module within 1 minute
of removal to prevent chassis overheating. Before removing the fan module,
ensure you have a replacement fan module at hand.
NOTE:
The fan module provides FRU-to-port or port-to-FRU airflow
depending on the switch product SKU you purchase. In legacy switches, or
switches with an LCD, this airflow is called front to back and back to front.
Chapter 44: Replacing QFX5100 Components
677