QFX3000-G QFabric System Hardware Documentation
126
Figure 87: FRU-to-Port Airflow Through the QFX3500 Chassis
FRUs
In the QFX3500 device models that have port-to-FRU airflow, the air intake to cool the
chassis is located on the rear panel of the chassis, the side with access and uplink ports.
Air is pulled into the chassis and pulled through the fan trays and management boards.
Hot air exhausts from the front of the chassis, where the FRUs are installed. See
Figure 88 on page
126.
Figure 88: Port-to-FRU Airflow Through the QFX3500 Chassis
FRUs
Each airflow type requires specific fan trays, management boards, and power supplies,
that have fan modules oriented in the proper direction. The fan trays and management
boards are designed so that they can only be inserted into the QFX3500 device model
that supports the same airflow type. The power supplies have labels and arrows on the
Copyright © 2018, Juniper Networks, Inc.
Ports
Ports