580
FM-0
Fabric control
FC-0
FC-1
Diagnostic routing engine
DRE-0
Director group
0281022011000011
0281032012000018
The Node device must show as
Start the orderly shutdown of the Node device by issuing the
3.
node-device
operational mode command from the QFabric default partition CLI. This
command systematically takes the node offline and gracefully shuts down the device
while preserving system state information. A message appears on the console or
console log, confirming that the operating system has stopped on the device.
You see the following output after entering the command:
root@qfabric> request fabric administration power-off node-device ED1491
STEP 1 of 8 (Acquiring lock):
Acquiring lock to perform this operation
Acquired lock to perform this operation
STEP 2 of 8 (Performing pre-checks):
node-device ED1491 is online
STEP 3 of 8 (Mastership switch-over):
node-device ED1491 is Server Node-group
STEP 4 of 8 (Gracefully offlining the node-device):
node-device is being offlined
node-device is successfully offlined
STEP 5 of 8 (Waiting for convergence):
Waiting for convergence(this will take few minutes)
Convergence complete
STEP 6 of 8 (Powering-off the node-device):
Now, powering-off the node-device
Powered-off the node-device
STEP 7 of 8 (Updating inventory):
Removing the node-device - ED1491 from inventory
node-device - ED1491 is removed from inventory
STEP 8 of 8 (Releasing lock):
Releasing the lock
root@qfabric>
CAUTION:
The final output of the
command is the following message:
be removed when the LCDs are off
seeing this message before following the instructions in Step
6
to disconnect the switch.
Attach the grounding strap to your bare wrist and to a site ESD point.
4.
Connected
Connected
Connected
Connected
Connected
Connected
and
to have an orderly shutdown.
connected
configured
request fabric power-off node-device
The device is shutting down and can