Table 76: Ex Series Switch Environmental Tolerances - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation

Table 76: EX Series Switch Environmental Tolerances

Environment Tolerance
Switch or
device
Altitude
EX2200-C
No performance
degradation up to
5,000 feet
(1524 meters)
EX2200
No performance
(except
degradation up to
EX2200-C
10,000 feet
switches)
(3048 meters)
EX2300-C
No performance
degradation up to
5,000 feet
(1524 meters)
EX2300
No performance
(except
degradation up to
EX2300-C
13,000 feet
switches)
(3962 meters) at
104° F (40° C) as per
GR-63
EX3200
No performance
degradation up to
10,000 feet
(3048 meters)
EX3300
No performance
degradation up to
10,000 feet
(3048 meters)
EX3400
No performance
degradation up to
10,000 feet
(3048 meters)
224
Table 76 on page 224
provides the required environmental conditions for normal switch
operation.
Relative Humidity
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Normal operation ensured
in the relative humidity
range 10% through 85%
(noncondensing)
Temperature
Normal operation ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
at altitudes up to 5,000 ft
(1,524 m).
For information about
extended temperature SFP
transceivers supported on
EX2200 switches, see
Pluggable Transceivers
Supported on EX2200
Switches.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Copyright © 2018, Juniper Networks, Inc.
Seismic
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone
4 earthquake
requirements as per
GR-63, Issue 4.

Advertisement