Installing a Fan Module in a QFX3100 Director Device
592

Figure 234: Removing a Fan Module from a QFX3100 Director Device

Loosen captive screws
Installing a Fan Module in a QFX3100 Director Device on page 592
Fan Modules in a QFX3100 Director Device on page 33
QFX3100 Director devices have three field-replaceable unit (FRU) fan modules on the
back panel. The fans are hot-removable and hot-insertable FRUs: You can remove and
replace them without powering off the QFX3100 Director device or disrupting QFX3100
Director device functions.
Before you begin installing a fan module in a QFX3100 Director device:
Ensure that you understand how to prevent electrostatic discharge (ESD) damage.
See
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you have the following parts and tools available:
ESD grounding strap
To install a fan module in a QFX3100 Director device (see
Attach the ESD grounding strap to your bare wrist, and connect the strap to a site ESD
1.
point.
Remove the fan module from its bag.
2.
Ensure that the fan module is properly aligned with the fan module slot.
3.
WARNING:
To avoid injury, do not touch the fan with your hands or any
tools as you slide the fan module into the chassis—the fan may start
running.
360.