Figure 193: Dc Power Supply Faceplate For A Qfx3500, Qfx3600 Or Qfx3600-I; Device; Figure 194: Securing Ring Lugs To The Terminals On The Qfx3500, Qfx3600 Or Qfx3600-Idc Power Supply - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

Copyright © 2018, Juniper Networks, Inc.
Figure 193: DC Power Supply Faceplate for a QFX3500, QFX3600 or QFX3600-I Device
2
8
7
1—
Shunt positive input terminals
2—
Shunt negative input terminals
3—
Terminal block
4—
Ejector lever
CAUTION:
The V+ terminals are shunted internally together, as are the
V- terminals. The same polarity terminal can be wired together from the
same source to provide an additional current path in a higher power
chassis. Do not connect the terminals to different sources.
Figure 194: Securing Ring Lugs to the Terminals on the QFX3500, QFX3600 or QFX3600-I
DC Power Supply
Replace the terminal block cover.
8.
Close the input circuit breaker.
9.
Chapter 32: Installing a QFX3600 Node Device
1
3
4
6
5
5—
ESD grounding point
6—
Fault LED
7—
Output LED
8—
Input LED
469