Juniper QFabric QFX3000-G Hardware Documentation page 638

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Removing a Power Supply from a QFX3100 Director Device (includes video)
588
Installing a Fan Module in a QFX3100 Director Device on page 592
Removing a Fan Module from a QFX3100 Director Device on page 590
Installing an HDD Module in a QFX3100 Director Device on page 601
Removing an HDD Module from a QFX3100 Director Device on page 599
Installing a Network Module in a QFX3100 Director Device on page 596
Removing a Network Module from a QFX3100 Director Device on page 593
Cooling System and Airflow in a QFX3100 Director Device on page 31
AC Power Supply in a QFX3100 Director Device on page 34
Network Modules in a QFX3100 Director Device on page 32
HDD Modules in a QFX3100 Director Device on page 33
The AC power supply in a QFX3100 Director device is a hot-removable and hot-insertable
field-replaceable unit (FRU) located on the far right side of the rear panel. Two AC power
supplies can be installed in a QFX3100 Director device. You can remove and replace a
single AC power supply without powering off the QFX3100 Director device or disrupting
QFX3100 Director device functions.
Before you remove an AC power supply from the QFX3100 Director device:
Ensure that you understand how to prevent electrostatic discharge (ESD) damage.
See
"Prevention of Electrostatic Discharge Damage" on page
Ensure that you have the following parts and tools available to remove an AC power
supply from a QFX3100 Director device:
ESD grounding strap
Antistatic bag or antistatic mat
Replacement power supply for the power supply slot
To remove an AC power supply from a QFX3100 Director device (see
Figure 232 on page
589):
Attach the ESD grounding strap to your bare wrist, and connect the strap to a site ESD
1.
point.
Remove the power cord from the AC appliance inlet on the AC power supply faceplate.
2.
Push the power supply faceplate ejector lever to the right while pulling the power
3.
supply away from the QFX3100 Director device to release the latch. Stop pulling the
power supply once the lever is released.
360.