Figure 245: Installing A Bottom Fan Tray In A Qfx3008-I Interconnect Device - Juniper QFabric QFX3000-G Hardware Documentation

Hide thumbs Also See for QFabric QFX3000-G:
Table of Contents

Advertisement

QFX3000-G QFabric System Hardware Documentation
Related
Documentation
Removing a Side Fan Tray from a QFX3008-I Interconnect Device
614
within 2 minutes of removing the fan tray to prevent overheating of the
chassis.
To install a fan tray in a QFX3008-I Interconnect device (see
Attach the ESD grounding strap to your bare wrist, and connect the strap to the ESD
1.
point on the chassis.
Hold the handle of the fan tray with one hand and support the weight of the tray with
2.
the other hand. Align the tray with the fan tray guides on the fan tray slot. Slide in the
fan tray until it is fully seated in the chassis.
Tighten the captive screw on the panel display using your fingers.
3.

Figure 245: Installing a Bottom Fan Tray in a QFX3008-I Interconnect Device

Removing a Bottom Fan Tray and Front Panel Display from a QFX3008-I Interconnect
Device on page 611
Cooling System and Airflow in a QFX3008-I Interconnect Device on page 48
A QFX3008-I Interconnect device has eight field-replaceable side fan trays. All eight side
fan trays are hot-removable and hot-insertable field-replaceable units (FRUs); you can
remove and replace the fan tray while the device is running without turning off power to
the device or disrupting device functions.
CAUTION:
Do not remove a fan tray unless you have a replacement fan tray
available.
Figure 245 on page
614):
Copyright © 2018, Juniper Networks, Inc.