Avaya S8700 Maintenance Manual page 122

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Alarms, Errors, and Troubleshooting
Sonet per-Port Statistics
---------------------------------
Receive Cell Count:
Transmit Cell Count:
Section Level Bit Err:
Line Bit Err:
Line FEB Err:
Path Bit Err:
Path FEB Err:
Correctable HCS Err:
Uncorrectable HCS Err:
Loss of Frame Err:
Loss of Signal Err:
Out of Frame Err:
Path Signal Label:
Figure 4-27. A500: show stats sonet a1.2 screen
2. Ensure that the fields have the following indicated values.
Receive
Cell Count
Transmit
Cell Count
4-48
Issue 1 May 2002
80654
79555
1
1
168
1
98
0
0
1
0
0
19
Each field's values should be increasing if the TN230X is
actively sending and receiving cells with the A500. (Even if
a TN230X did not achieve board insertion, it will still try to
talk to the A500.)
If neither field is increasing, the A500 port may have been
marked down using the admin down command. Use the
show system interfaces command to verify that the
Admin Status
is up.
If the
Receive Cell Count
Transmit Cell Count
because the port was administered with no UNI signaling
(admin link command). Use the show signaling summary
command to ensure that
The error counters may not be zero, but should not be large
either compared to the receive and transmit cell counters. If
the counters are large and increasing, check the fiber
integrity. Make sure the fiber pairs are securely plugged into
both the TN230X and the A500.
If the fiber has been pulled and reinserted as part of fault
diagnosis, the non-zero
may be correct.
is increasing but the
is not increasing, this may be
Signaling
is
UNI3.1
Loss of Signal Err
555-233-143
.
counter