show sflow pollers

Usage
A poller instance performs counter sampling on the data source to which it is configured. Refer to 
"Sampling Mechanisms" on page 28‐2 for more information.
You must first associate a receiver/Collector in the sFlow Receivers Table with the poller instance, 
before configuring the polling interval.
When a receiver times out or is cleared from the sFlow Receivers Table, all poller and sampler 
instances associated with that receiver are also cleared from the switch's configuration.
Example
The following example configures poller instances on ports ge.1.1 through ge.1.8 and associates 
them with receiver 1. Then, a polling interval of 240 seconds is configured.
C3(su)->set sflow port ge.1.1-8 poller 1
C3(su)->set sflow port ge.1.1-8 poller interval 240
show sflow pollers
Use this command to display information about configured poller instances.
Syntax
show sflow pollers
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example displays the output of this command.
C3(su)->show sflow pollers
Poller
Data Source
-----------
ge.1.1
ge.1.2
ge.1.3
ge.1.4
ge.1.5
ge.1.6
ge.1.7
ge.1.8
Receiver
Poller
Index
Interval
-------
-------
1
240
1
240
1
240
1
240
1
240
1
240
1
240
1
240