Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets port 1 to wait 5 seconds after a failed authentication attempt before a new 
attempt can be made:
C3(su)->set macauthentication portquietperiod 5 ge.1.1

clear macauthentication portquietperiod

This sets the quiet period back to the default value of 30 seconds.
Syntax
clear macauthentication portquietperiod [port-string]
Parameters
port‐string
Defaults
If a port‐string is not specified then all ports will be set to the default port quiet period.
Mode
Switch command, read‐write.
Example
This example resets the default quiet period on port 1:
C3(su)->clear macauthentication portquietperiod ge.1.1

set macauthentication macinitialize

Use this command to force a current MAC authentication session to re‐initialize and remove the 
session.
Syntax
set macauthentication macinitialize mac-addr
Parameters
mac‐addr
(Optional) Specifies the ports for which the quiet period is to be reset. For a 
detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 7‐1. 
Specifies the MAC address of the session to re‐initialize.
clear macauthentication portquietperiod
SecureStack C3 Configuration Guide 26-31