set lldp hold-multiplier

Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets the transmit interval to 20 seconds. 
C3(rw)->set lldp tx-interval 20
set lldp hold-multiplier
Use this command to set the time‐to‐live value used in LLDP frames sent by this device. The time‐
to‐live for LLDPDU data is calculated by multiplying the transmit interval by the hold multiplier 
value.
Syntax
set lldp hold-multiplier multiplier-val
Parameters
multiplier‐val
Defaults
None.
Mode
Switch command, read‐write.
Example
This example sets the transmit interval to 20 seconds and the hold multiplier to 5, which will 
configure a time‐to‐live of 100 to be used in the TTL field in the LLDPDU header.
C3(rw)->set lldp tx-interval 20
C3(rw)->set lldp hold-multiplier 5

set lldp trap-interval

Use this command to set the minimum interval between LLDP notifications sent by this device. 
LLDP notifications are sent when a remote system change has been detected.
Syntax
set lldp trap-interval frequency
6-24 Discovery Protocol Configuration
Specifies the multiplier to apply to the transmit interval to determine 
the time‐to‐live value. Value can range from 2 to 10. Default value is 4.