Clear Garp Timer - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

leaveall timer‐
value
port‐string
Defaults
None.
Mode
Switch command, read‐write.
Usage
The setting of these timers is critical and should only be changed by personnel familiar with the 
802.1Q standards documentation, which is not supplied with this device.
Examples
This example shows how to set the GARP join timer value to 100 centiseconds for all ports:
C3(su)->set garp timer join 100 *.*.*
This example shows how to set the leave timer value to 300 centiseconds for all ports:
C3(su)->set garp timer leave 300 *.*.*
This example shows how to set the leaveall timer value to 20000 centiseconds for all ports:
C3(su)->set garp timer leaveall 20000 *.*.*

clear garp timer

Use this command to reset GARP timers back to default values.
Syntax
clear garp timer {[join] [leave] [leaveall]} port-string
Parameters
join
leave
leaveall
port‐string
Defaults
At least one optional parameter must be entered.
Mode
Switch command, read‐write.
Sets the GARP leaveall timer in centiseconds (Refer to 802.1Q standard.)
Specifies the port(s) on which to configure GARP timer settings. For a 
detailed description of possible port‐string values, refer to "Port String 
Syntax Used in the CLI" on page 7‐1.
(Optional) Resets the join timer to 20 centiseconds.
(Optional) Resets the leave timer to 60 centiseconds.
(Optional) Resets the leaveall time to 1000 centiseconds.
Specifies the port or ports on which to reset the GARP timer(s).
clear garp timer
SecureStack C3 Configuration Guide 10-25

Hide quick links: