clear maclock agefirstarrival
Mode
Switch mode, read‐write.
Example
This example enables first arrival aging on port
C3(su)-> set maclock agefirstarrival ge.1.1 enable
clear maclock agefirstarrival
Use this command to reset first arrival aging on one or more ports to its default state of disabled.
Syntax
clear maclock agefirstarrival port-string
Parameters
port‐string
Defaults
None.
Mode
Switch mode, read‐write.
Example
This example disables first arrival aging on port
C3(su)-> clear maclock agefirstarrival ge.1.1 enable
set maclock move
Use this command to move all current first arrival MACs to static entries.
Syntax
set maclock move port-string
Parameters
port‐string
Defaults
None.
26-66 Authentication and Authorization Configuration
Specifies the port(s) on which to disable first arrival aging. For a
detailed description of possible port‐string values, refer to "Port String
Syntax Used in the CLI" on page 7‐1.
Specifies the port on which MAC will be moved from first arrival MACs
to static entries. For a detailed description of possible port‐string values,
refer to "Port String Syntax Used in the CLI" on page 7‐1.
.1.1.
ge
.1.1.
ge
Need help?
Do you have a question about the SECURESTACK C3 and is the answer not in the manual?
Questions and answers