Example
This example shows how to set the severity level for SNMP to 4 so that error conditions will be
logged for that application.
C3(rw)->set logging application SNMP level 4
clear logging application
Use this command to reset the logging severity level for one or all applications to the default value
of 6 (notifications of significant conditions).
Syntax
clear logging application {mnemonic | all}
Parameters
mnemonic
all
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to reset the logging severity level to 6 for SNMP.
C3(rw)->clear logging application SNMP
show logging local
Use this command to display the state of message logging to the console and a persistent file.
Syntax
show logging local
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Resets the severity level for a specific application to 6. Valid mnemonic
values and their corresponding applications are listed in Table
page 14‐8.
Resets the severity level for all applications to 6.
clear logging application
SecureStack C3 Configuration Guide 14-9
14‐3 on