Show Port Inlinepower - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

show port inlinepower

Parameters
auto
ieee
Defaults
Default detection mode is auto.
Mode
Switch command, read‐write.
Usage
This command is used to specify how the switch should detect PDs connected to its ports. The PoE 
hardware in the switches can use the IEEE standard 802.3af (resistor‐based) method or a 
proprietary method using capacitor detection. 
If auto is configured, the switch will first use the IEEE resistor‐based detection method, and if that 
fails, the switch will use the capacitor‐based detection method. If ieee is configured, only the IEEE 
resistor‐based detection method will be used.
Example
This example sets the switch's PD detection mode to IEEE standard 802.3af only.
C3
(su)->set inlinepower detectionmode ieee
show port inlinepower
Use this command to display all ports supporting PoE. 
Syntax
show port inlinepower [port-string]
Parameters
port‐string
Defaults
If not specified, information for all PoE ports will be displayed.
Mode
Switch command, read‐only.
Example
This example shows how to display PoE information for port 
administrative state, PoE priority and class have not been changed from default values:
5-4 Configuring System Power and PoE
Specifies that the switch will use the standard 802.3af detection method 
first. If that fails, then the switch will use the legacy (pre 802.3af 
standard) capacitance method of detection.
Specifies that the switch will only use the standard 802.3af detection 
method.
(Optional) Displays information for specific PoE port(s).
. In this case, the port's 
ge.2.1

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SECURESTACK C3 and is the answer not in the manual?

Questions and answers

Table of Contents