Parameters
syslog enable |
disable
trap enable | disable
overtemp‐threshold
value
Defaults
Syslog alerts are disabled by default.
Trap alerts are disabled by default.
Overtemp threshold is 100% by default.
Mode
Switch command, read‐write.
Usage
On the platforms that support this feature, temperature sensors are located in several different
locations within the device. Threshold calibrations have been calculated separately for each
platform. The thermal overtemp threshold is the high‐water mark that, when reached, triggers an
alert to warn the system administrator that the device is operating at high temperatures.
When a high temperature alert condition occurs, the CPU LED on the front panel of the switch
will flash red. In addition, if enabled, a syslog message will be logged and/or an SNMP trap will
be sent.
The values set with this command can be viewed with the show system command.
Example
The following example enables sending SNMP traps and sets the overtemp threshold to 60%.
C3(su)->set system temperature trap enable overtemp-threshold 60
clear system temperature
Use this command to reset system high temperature parameters to their default values, on the
platforms that support this feature.
Syntax
clear system temperature
Parameters
None.
Defaults
None.
Enables or disables logging high temperature alerts to the system log
when the system transitions into an alarm state.
Enables or disables sending high temperature alerts by means of SNMP
traps when the system transitions into an alarm state.
Sets the thermal threshold as a percentage of the maximum rated for the
specific platform. Value can range from 0 to 100%.
clear system temperature
SecureStack C3 Configuration Guide 3-19
Need help?
Do you have a question about the SECURESTACK C3 and is the answer not in the manual?