Set Sflow Port Poller - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

sFlow Configuration
owner
timeout
port port
Defaults
If no optional parameters are specified, the entire entry is cleared.
Mode
Switch command, read‐write.
Usage
You can clear the IP address, maximum datagram size, or UDP port without deleting an entry 
from the sFlow Receivers Table. If you clear the owner or timeout, the entire entry is cleared. If you 
enter only an entry index and none of the optional parameters, the entire entry is cleared.
Once an entry is cleared, all pollers and samplers associated with that receiver are also removed 
from the switch configuration.
Example
This example returns the maximum datagram size to the default of 1400 bytes for the Collector 
with index 1.
C3(su)->clear sflow receiver 1 maxdatagram

set sflow port poller

Use this command to configure poller instances on ports, or data sources.
Syntax
set sflow port port-string poller {index | interval seconds}
Parameters
port‐string
index
interval seconds
Defaults
The default interval value is 0 seconds, which disables counter sampling.
Mode
Switch command, read‐write.
28-10
(Optional) Clear the owner identity string. Entries in the sFlow Receiver 
Table without an identity string are considered unclaimed.
(Optional) Clear the timeout value of the specified entry. 
(Optional) Clear the UDP port on the receiver/Collector to which the 
sample datagrams should be sent. The value is reset to the default of 
6343.
Specifies the port or ports (data sources) on which the poller instance is 
being configured.
Index number in the sFlow Receivers Table for the receiver/Collector 
with which the poller instance is associated. The index can range from 1 
to 8.
Specifies the polling interval, which can range from 0 to 86400 seconds. 
A value of 0 disables counter sampling.
set sflow port poller

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents