Set Port Inlinepower - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

C3(su)->show port inlinepower ge.2.1
Port
----
ge.2.1

set port inlinepower

Use this command to configure PoE parameters on one or more ports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
port‐string
admin off | auto
priority critical | 
high | low
type type
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to enable PoE on port 
C3(su)->set port inlinepower ge.3.1 admin auto priority critical
Type
Admin
Oper
----
-----
----
wireless
auto
searching
Specifies the port(s) on which to configure PoE.
Sets the PoE administrative state to off (disabled) or auto (on).
Sets the port(s) priority for the PoE allocation algorithm to critical 
(highest), high or low.
Specifies a string describing the type of device connected to a port.
Priority
Class
--------
-----
low
0
3.1 with critical priority:
ge.
SecureStack C3 Configuration Guide 5-5
set port inlinepower
Power(W)
--------
15.4