IPv6 operation, however, because shorter times consume more IPv6 network bandwidth and 
processing resources. 
This value is also included in all Router Advertisements messages sent out on the interface. By 
default, a value of 0, indicating that the configured time is unspecified by this router, is sent out in 
RA messages. 
Use the no form of this command to reset this value to the default.
The show ipv6 interface command displays the current reachable time setting.
Example
This example sets the reachable time to 60 seconds.
C3(su)->router(Config-if(Vlan 1))# ipv6 nd reachable-time 60000

ipv6 nd other-config-flag

This command sets the "other stateful configuration" flag in router advertisements sent on this 
interface to true.
Syntax
ipv6 nd other-config-flag
no ipv6 nd other-config-flag
Parameters
None.
Defaults
Flag is set to false by default.
Mode
Router interface configuration: C3(su)‐>router(Config‐if (Vlan 1))#
Usage
When the value of the "other stateful configuration" flag is true, end nodes should use stateful 
autoconfiguration (DHCPv6) to obtain additional information (excluding addresses). When the 
value is false, end nodes do not. Refer to RFC 2462, "IPv6 Stateless Address Autoconfiguration," 
for more information.
Use the no form of this command to reset the flag to false.
Example
This example sets the other stateful configuration flag to true.
C3(su)->router(Config-if(Vlan 1))# ipv6 nd other-config-flag
ipv6 nd other-config-flag