set spantree bpdu-forwarding

set spantree bpdu-forwarding
Use this command to enable or disable Spanning Tree BPDU forwarding. By default BPDU 
forwarding is disabled.
Syntax
set spantree bpdu-forwarding {disable | enable}
Parameters
disable | enable
Defaults
By default BPDU forwarding is disabled.
Mode
Switch command, read‐write.
Usage
The Spanning Tree protocol must be disabled (set spantree disable) for this feature to take effect.
Example
This example shows how to enable BPDU forwarding:
C3(rw)-> set spantree bpdu-forwarding enable

show spantree bridgeprioritymode

Use this command to display the Spanning Tree bridge priority mode setting.
Syntax
show spantree bridgeprioritymode
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example shows how to display the Spanning Tree bridge priority mode setting: 
C3(rw)->show spantree bridgeprioritymode
Bridge Priority Mode is set to IEEE802.1t mode.
9-10 Spanning Tree Configuration