set vlan egress
Use this command to add ports to the VLAN egress list for the device, or to prevent one or more
ports from participating in a VLAN. This determines which ports will transmit frames for a
particular VLAN.
Syntax
set vlan egress vlan-list port-string [untagged | forbidden | tagged]
Parameters
vlan‐list
port‐string
untagged |
forbidden |
tagged
Defaults
If untagged, forbidden or tagged is not specified, the port will be added to the VLAN egress list
as tagged.
Mode
Switch command, read‐write.
Examples
This example shows how to add
these ports will transmit VLAN 7 frames as tagged
C3(su)->set vlan egress 7 ge.1.5-10 untagged
This example shows how to forbid ports 13 through 15 in slot 1 from joining VLAN 7 and disallow
egress on those ports:
C3(su)->set vlan egress 7 ge.1.13-15 forbidden
This example shows how to allow port 2 in slot 1 to transmit VLAN 7 frames as untagged
C3(su)->set vlan egress 7 ge.1.2 untagged
clear vlan egress
Use this command to remove ports from a VLAN's egress list.
Specifies the VLAN where a port(s) will be added to the egress list.
Specifies one or more ports to add to the VLAN egress list of the specified
vlan‐list. For a detailed description of possible port‐string values, refer to
"Port String Syntax Used in the CLI" on page 7‐1.
(Optional) Adds the specified ports as:
•
untagged — Causes the port(s) to transmit frames without an IEEE
802.1Q header tag.
•
forbidden — Instructs the device to ignore dynamic requests (either
through GVRP or dynamic egress) from the port(s) to join the VLAN
and disallows egress on that port.
•
tagged — Causes the port(s) to transmit 802.1Q tagged frames.
Note: The following command will reset the specified port's egress status to tagged. To set the
specified ports back to the default egress status of untagged, you must issue the
command as described on page 10-15.
1.5 through 10 to the egress list of VLAN 7. This means that
ge.
:
set vlan egress
SecureStack C3 Configuration Guide 10-15
set vlan egress
: