Usage
The no form of this command resets the lifetime value to the default of 1800 seconds.
Example
This example sets the router advertisement lifetime value to 3600 seconds.
C3(su)->router(Config-if(Vlan 1))# ipv6 nd ra-lifetime 3600

ipv6 nd suppress-ra

This command suppresses router advertisement transmission on this interface.
Syntax
ipv6 nd suppress-ra
no ipv6 nd suppress-ra
Parameters
None.
Defaults
Suppression disabled.
Mode
Router interface configuration: C3(su)‐>router(Config‐if(Vlan 1))#
Usage
By default, transmission of router advertisements is enabled. This command disables such 
transmissions. Use the no form of this command to re‐enable transmission.
Example
This example disables router advertisement transmission. 
C3(su)->router(Config-if(Vlan 1))# ipv6 nd suppress-ra

ipv6 nd prefix

This command configures the IPv6 prefixes to be included in router advertisements sent by this 
interface.
Syntax
ipv6 nd prefix {ipv6-prefix/prefix-length} [{valid-lifetime | infinite}
{preferred-lifetime | infinite}] [no-autoconfig] [off-link]
no ipv6 nd prefix {ipv6-prefix/prefix-length}
ipv6 nd suppress-ra
SecureStack C3 Configuration Guide 22-19