Set Sflow Receiver Port; Clear Sflow Receiver - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

set sflow receiver port

Mode
Switch command, read‐write.
Example
This example sets the maximum datagram size to 2800 bytes for index entry 1.
C3(su)->set sflow receiver 1 maxdatagram 2800
set sflow receiver port
Use this command to configure the UDP port on the sFlow Controller to which the switch will 
send sample datagrams.
Syntax
set sflow receiver index port port
Parameters
index
port port
Defaults
The default port value is 6343.
Mode
Switch command, read‐write.
Example
This example changes the sFlow receiver port on the Collector to 1234.
C3(su)->set sflow receiver 1 port 1234

clear sflow receiver

Use this command to delete a receiver/Collector from the sFlow Receivers Table, or to return 
certain parameters to their default values for the specified Collector.
Syntax
clear sflow receiver index [ip | maxdatagram | owner [timeout] | port]
Parameters
index
ip
maxdatagram
Index number in the sFlow Receivers Table for the receiver/Collector 
being configured. The index can range from 1 to 8.
Specifies the UDP port on the receiver/Collector to which the sample 
datagrams should be sent. By default, the port is 6343.
Index number in the sFlow Receivers Table for the receiver/Collector 
being configured. The index can range from 1 to 8.
(Optional) Clear the IP address to 0.0.0.0. Sample datagrams are not sent 
to Collectors with an IP address of 0.0.0.0.
(Optional) Return the maximum datagram size to 1400 bytes.
sFlow Configuration
SecureStack C3 Configuration Guide 28-9