Example Configuration; Commands - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

sFlow Configuration
sFlow is disabled by default on SecureStack and G‐Series devices. 

Example Configuration

The general procedure for configuring sFlow includes:
1.
Configure your sFlow Collector information to be used by the sFlow Agent on the switch. Up 
to eight Collectors can be configured. The information is stored in the sFlowReceiverTable.
2.
Enable and configure sFlow packet flow sampling instances on each port.
3.
Enable and configure sFlow counter sampling poller instances on each port.
The following is an example of the commands used to configure sFlow:
# configure sFlow Collector 1
# accept defaults for datagram size and port
set sflow receiver 1 owner enterasys timeout 180000
set sflow receiver 1 ip 192.168.16.91
#
#configure packet sampling instances on ports 1 through 12
#assign to sFlow Collector 1
set sflow port ge.1.1-12 sampler 1
set sflow port ge.1.1-12 sampler maxheadersize 256
set sflow port ge.1.1-12 sampler rate 2048
#
#configure counter poller instances on ports 1 through 12
#assign to sFlow Collector 1
set sflow port ge.1.1-12 poller 1
set sflow port ge.1.1-12 poller interval 20

Commands

For information about...
show sflow receivers
set sflow receiver owner
set sflow receiver ip
set sflow receiver maxdatagram
set sflow receiver port
clear sflow receiver
set sflow port poller
show sflow pollers
clear sflow port poller
set sflow port sampler
show sflow samplers
clear sflow port sampler
28-4
Commands
Refer to page...
28-5
28-7
28-7
28-8
28-9
28-9
28-10
28-11
28-12
28-12
28-13
28-14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents