Set Sflow Receiver Maxdatagram - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

sFlow Configuration
Parameters
index
ip ipaddr
Defaults
The default IP address is 0.0.0.0.
Mode
Switch command, read‐write.
Usage
In order for an sFlow Collector to be assigned to receive sample datagrams from the sFlow Agent 
on the switch, an entry for that Collector must be configured in the switch's sFlow Receivers Table. 
An entry must contain an owner identity string, a non‐zero timeout value, and the IP address of 
the Collector. Configure the owner identity string and timeout value with the set sflow receiver 
owner command.
Sample datagrams will not be sent to a Collector whose entry in the sFlow Receivers Table has an 
IP address of 0.0.0.0.
Example
This example configures an IP address of 10.10.10.10 to index entry 1.
C3(su)->set sflow receiver 1 ip 10.10.10.10

set sflow receiver maxdatagram

Use this command to set the maximum number of data bytes that can be sent in a single sample 
datagram.
Syntax
set sflow receiver index maxdatagram bytes
Parameters
index
maxdatagram bytes
Defaults
Default maximum datagram size is 1400 bytes.
28-8
Index number in the sFlow Receivers Table for the receiver/Collector 
being configured. The index can range from 1 to 8.
The IP address of the receiver/Collector being configured. An IP 
address of 0.0.0.0 means that no sample datagrams will be sent to the 
Collector.
Index number in the sFlow Receivers Table for the receiver/Collector 
being configured. The index can range from 1 to 8.
Specifies the maximum number of data bytes that can be sent in a single 
sample datagram. This size should be set to avoid fragmentation of the 
sFlow datagrams.
The value of bytes can range from 200 to 9116. The default is 1400.
set sflow receiver maxdatagram