Show Sflow Receivers Output Descriptions - Enterasys SECURESTACK C3 Configuration Manual

Stackable switches
Hide thumbs Also See for SECURESTACK C3:
Table of Contents

Advertisement

sFlow Configuration
This example displays information about the Collector with index 1.
C3(su)->show sflow receivers 1
Receiver Index
Owner String
Time out
IP Address:
Address Type
Port
Datagram Version
Maximum Datagram Size
The following table describes the output fields.
Table 28-2 show sflow receivers Output Descriptions
Output...
Receiver Index
Owner String
Time Out
IP Address
Address Type
Port
Datagram Version
Max Datagram Size
28-6
1
ets1
17758
10.1.2.117
IPv4
6343
5
1400
What it displays...
Index number of a specific Collector entry in the sFlow Receivers
Table. Up to 8 Collectors may be configured.
Identity string of the Collector. An empty string indicates that the
entry is unclaimed and cannot be assigned to a sampler or poller
instance. The owner string is configured with the
owner
command.
The time remaining, in seconds, before the sampler or poller is
released and stops sending samples to this receiver/Collector.
The timeout value is configured with the
command.
The IP address of this receiver/Collector. The IP address is
configured with the
set sflow receiver ip
Whether the Collector IP address is IPv4 or IPv6.
The UDP port number on this receiver/Collector to which sample
datagrams should be sent. The default value is 6343, which can
be changed with the
set sflow receiver port
Specifies the sFlow version used for formatting the sample
datagrams.
The maximum number of data bytes that can be sent in a single
sample datagram to this receiver/Collector. The default value is
1400 bytes, which can be changed with the
maxdatagram
command.
show sflow receivers
set sflow receiver
set sflow receiver owner
command.
command.
set sflow receiver

Hide quick links:

Advertisement

Table of Contents
loading