Cisco ONS 15454 Series Procedure Manual page 343

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 13
Convert Network Configurations
NTP-A267 Convert a Path Protection to a Two-Fiber BLSR
Automatically
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Open-ended path protection and path protection dual-ring interconnect (DRI) configurations do not
Note
support in-service topology upgrades.
Before beginning this procedure, you should have a unique ring name to identify the new BLSR and a
Note
unique node ID number for each node on the ring.
Before beginning this procedure, optical transmit and receive levels should be in their acceptable range
Note
as shown in
If overhead circuits exist on the network, this procedure is service affecting. The overhead circuits will
Note
drop traffic and have a status of PARTIAL after the upgrade is complete.
Complete the
Step 1
already logged in, continue with Step 2.
Complete the
Step 2
In the UPSR to BLSR Topology Conversion dialog box, set the BLSR properties:
Step 3
December 2004
This procedure converts a path protection to a two-fiber BLSR without
disrupting traffic.
None
NTP-A44 Provision Path Protection Nodes, page 5-20
As needed
Onsite or remote
Provisioning or higher
Table 2-3 on page
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A298 Check the Network for Alarms and Conditions" task on page
Ring Type—(Display only.) The default is two-fiber.
Speed—Choose the BLSR ring speed: OC-12, OC-48, or OC-192. The speed must match the OC-N
speed of the BLSR trunk (span) cards.
Note
If you are creating an OC-12 BLSR and will eventually upgrade it to OC-48 or OC-192, use
the single-port OC-12 cards (OC12 IR/STM4 SH 1310, OC12 LR/STM4 SH 1310, or
OC12 LR/STM4 LH 1550).
Ring Name—Assign a ring name. The name can be from 1 to 6 characters in length. Any
alphanumeric string is permissible, and upper and lower case letters can be combined. Do not use
the character string "All" in either upper or lower case letters. This is a TL1 keyword and will be
rejected. Do not choose a name that is already assigned to another BLSR.
NTP-A267 Convert a Path Protection to a Two-Fiber BLSR Automatically
2-15.
at a node on the path protection. If you are
Cisco ONS 15454 Procedure Guide, R5.0
19-63.
13-13

Advertisement

Table of Contents
loading