Chapter 18
DLPs A100 to A199
Table 18-8
Parameter
SES
LOSS
Table 18-9
Table 18-9
Parameter
Port
EB
BBE
ES
SES
UAS
AISS
Table 18-10
Table 18-10
Parameter
Port
CV
March 2007
DLP-A166 Change Line and Threshold Settings for the DS3-12 or DS3N-12 Cards
Line Threshold Options for DS3-12 or DS3N-12 Cards (continued)
Description
Severely errored seconds
Loss of signal seconds; number of
one-second intervals containing one or
more LOS defects
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS-3 cards.
Electrical Path Threshold Options for DS3-12 or DS3N-12 Cards
Description
(Display only.) Port number
Errored blocks
Background block errors
Errored seconds
Severely errored seconds
Unavailable seconds
Alarm indication signal
describes the values on the Provisioning > SONET Thresholds tabs for the DS-3 cards.
SONET Threshold Options for DS3-12 or DS3N-12 Cards
Description
(Display only.) DS-3 ports partitioned for
STS
Coding violations
Options
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds.
Options
1 to 12
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds (DS3 Pbit: Near End
only; DS3 CPbit: Near and Far End).
Options
Line 1, STS 1, Line 2, STS 1
Line 3, STS 1, Line 4 STS 1
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds (Near and Far
End, STS termination only).