Figure - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 7
Manage Alarms
Note
Complete the
Step 3
suppression and resume normal alarm reporting.
Stop. You have completed this procedure.
NTP-A32 Provision External Alarms and Controls on the Alarm
Interface Controller
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
For information about the AIC external alarms and controls, virtual wire, and orderwire, refer to the
Note
Cisco ONS 15454 Reference Manual.
Verify the backplane wiring. See the
Step 1
Connections" procedure on page 1-15
a.
b.
Complete the
Step 2
Step
In the node view, double-click the AIC card on the shelf graphic. The card view appears.
Step 3
If you are provisioning external alarms, click the Provisioning > External Alarms tab
Step 4
you are not provisioning external alarms, skip Steps
December 2004
Suppressing one or more alarms prevents them from appearing in Alarm or History windows or
in any other clients. The suppress command causes CTC to display them in the Conditions
window with their severity, their severity color code, and service-affecting status.
"DLP-A523 Discontinue Alarm Suppression" task on page 22-19
Use this procedure to create external (environmental) alarms and external
controls on the Alarm Interface Controller (AIC).
An AIC card must be installed in Slot 9.
NTP-A24 Verify Card Installation, page 4-2
As needed
Onsite or remote
Provisioning or higher
For external alarms, verify that the external-device relays are wired to the ENVIR ALARMS IN
backplane pins.
For external controls, verify that the external relays are wired to the ENVIR ALARMS OUT
backplane pins.
"DLP-A60 Log into CTC" task on page
3.
NTP-A32 Provision External Alarms and Controls on the Alarm Interface Controller
"NTP-A8 Attach Wires to Alarm, Timing, LAN, and Craft Pin
for information about the ONS 15454 backplane pins.
17-66. If you are already logged in, continue with
5
through
Cisco ONS 15454 Procedure Guide, R5.0
to discontinue alarm

(Figure

7
and go to
Step
8.
7-4). If
7-9

Advertisement