Manage Alarms
To provision additional external controls, complete Steps
Step 10
Click Apply.
Step 11
Note
Note
Note
Stop. You have completed this procedure.
NTP-A258 Provision External Alarms and Controls on the Alarm
Interface Controller-International
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The AIC-I card alarm provides direct alarm contacts (external alarm inputs and external control outputs)
Note
routed through the backplane to wire-wrap pins accessible from the back of the shelf. If you install an
Alarm Expansion Panel (AEP), the AIC-I alarm contacts cannot be used. Only the AEP alarm contacts
can be used. For further information about the AEP, see
procedure on page 1-12
on page
For information about the AIC-I alarms, controls, and virtual wires, refer to the
Note
Cisco ONS 15454 Reference Manual.
December 2004
NTP-A258 Provision External Alarms and Controls on the Alarm Interface Controller-International
If you provision an external alarm to raise upon an open contact before you physically connect
to the ONS equipment, the alarm will raise until you do create the physical connection.
When you provision an external alarm, the alarm object is ENV-IN-nn. The variable nn refers to
the external alarm's number, regardless of the name you assign.
Environmental alarms that you create (and name) should be recorded locally for the NE. Both
the Alarm name and resolution are node-specific.
Use this procedure to create external (environmental) alarms and external
controls for the AIC-I card.
An AIC-I card must be installed in Slot 9.
NTP-A24 Verify Card Installation, page 4-2
As needed
Onsite or remote
Provisioning or higher
and the
"NTP-A120 Install an External Wire-Wrap Panel to the AEP" procedure
1-16.
8
and
9
for each additional device.
"NTP-A119 Install the Alarm Expansion Panel"
Cisco ONS 15454 Procedure Guide, R5.0
7-11

Advertisement

Table of Contents
loading

Table of Contents