NTP-A183 Create a Unidirectional DS-1 Circuit with Multiple Drops
If you entered more than 1 in the Number of Circuits field, the Circuit Creation dialog box appears so
Step 19
you can create the remaining circuits. Repeat Steps
When all the circuits are created, the main Circuits window appears. Verify that the circuits you created
Step 20
are correct.
Complete the
Step 21
test circuit.
Stop. You have completed this procedure.
NTP-A183 Create a Unidirectional DS-1 Circuit with Multiple
Drops
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
From the View menu, choose Go to Network View.
Step 3
Click the Circuits tab, then click Create.
Step 4
In the Circuit Creation dialog box, complete the following fields:
Step 5
Click Next.
Step 6
Define the circuit attributes
Step 7
Cisco ONS 15454 Procedure Guide, R5.0
6-14
"NTP-A135 Test Electrical Circuits" procedure on page
This procedure creates a unidirectional DS-1 circuit with multiple drops
(destinations).
None
NTP-A127 Verify Network Turn Up, page 6-4
As needed
Onsite or remote
Provisioning or higher
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A314 Assign a Name to a Port" task on page
Circuit Type—Choose VT.
Number of Circuits—Leave the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
(Figure
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—VT1.5 is the default. You cannot change it.
Bidirectional—Uncheck for this circuit.
Create cross-connects only (TL1-like)—Check this box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. Also, VT tunnels and
Ethergroup sources and destinations are unavailable.
5
through
at the node where you will create the circuit.
Step
2.
6-3):
Chapter 6
Create Circuits and VT Tunnels
18
for each additional circuit.
6-36. Skip this step if you built a
20-8. If not, continue with
Step
3.
August 2005