NTP-A174 Linear ADM Network Acceptance Test
NTP-A174 Linear ADM Network Acceptance Test
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
are testing. If you are already logged in, continue with Step 2.
From the View menu, choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
c.
Click the Conditions tab.
Step 4
a.
b.
On the network map, double-click the linear ADM node you are testing to open it in node view.
Step 5
Create a test circuit from that node to an adjacent linear ADM node.
Step 6
Configure the test set for the test circuit type you created:
Step 7
Cisco ONS 15454 Procedure Guide, R5.0
5-8
This procedure tests a linear ADM network.
Test set and cables appropriate to the test circuit you will create.
NTP-A38 Provision a Linear ADM Network, page 5-6
As needed
Onsite
Provisioning and higher
"DLP-A60 Log into CTC" task on page 17-66
Verify that the alarm filter is not on. See the
page 19-17
as necessary.
Verify that no unexplained alarms appear on the network. If unexplained alarms appear, resolve
them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide if necessary.
Complete the
"DLP-A516 Export CTC Data" task on page 22-6
Verify that no unexplained conditions appear on the network. If unexplained conditions appear,
resolve them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide if necessary.
Complete the
"DLP-A516 Export CTC Data" task on page 22-6
information.
For DS-1 circuits, complete the
procedure on page
6-6. When you set the circuit state, choose IS and check the Apply to drop ports
check box.
For DS-3 circuits, complete the
procedure on page
6-18. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
For OC-N circuits, complete the
procedure on page
6-38. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
DS-1 card—If you are testing a DS-1 that is not multiplexed, you must have a DSX-1 panel or a
direct DS-1 interface into the ONS 15454. Set the test set for DS-1. For information about
configuring your test set, consult your test set user guide.
DS-3—If you are testing a clear channel DS-3, you must have a DSX-3 panel or a direct DS-3
interface into the ONS 15454. Set the test set for clear channel DS-3. For information about
configuring your test set, consult your test set user guide.
on a node in the linear ADM network you
"DLP-A227 Disable Alarm Filtering" task on
"NTP-A181 Create an Automatically Routed DS-1 Circuit"
"NTP-A184 Create an Automatically Routed DS-3 Circuit"
"NTP-A257 Create an Automatically Routed OC-N Circuit"