NTP-A184 Create an Automatically Routed DS-3 Circuit
Complete the
Step 26
test circuit.
Stop. You have completed this procedure.
NTP-A184 Create an Automatically Routed DS-3 Circuit
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Complete the
If you are already logged in, continue with
Step 2
If you want to assign a name to the circuit source and destination ports before you create the circuit,
complete the
Step 3
From the View menu, choose Go to Network View.
Step 4
Click the Circuits tab, then click Create.
In the Circuit Creation dialog box, complete the following fields:
Step 5
Click Next.
Step 6
Define the circuit attributes
Step 7
Cisco ONS 15454 Procedure Guide, R5.0
6-18
"NTP-A135 Test Electrical Circuits" procedure on page
This procedure creates an automatically routed DS-3 circuit and also gives
you the option of creating a circuit over a pair of portless transmultiplexing
interfaces. CTC routes the circuit automatically based on circuit creation
parameters and the software version.
For portless transmultiplexing configurations, a DS3XM-12 must be
installed on a node through which the circuit will be routed.
NTP-A127 Verify Network Turn Up, page 6-4
As needed
Onsite or remote
Provisioning or higher
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A314 Assign a Name to a Port" task on page
Circuit Type—Choose STS. STS cross-connects will carry the DS-3 circuit across the ONS 15454
network.
Number of Circuits—Enter the number of DS-3 circuits you want to create. The default is 1. If you
are creating multiple circuits with sequential source and destination ports, you can use Auto-ranged
to create the circuits automatically.
Auto-ranged—This box is automatically selected if you enter more than 1 in the Number of Circuits
field. Leave selected if you are creating multiple DS-3 circuits with the same source and destination
and you want CTC to create the circuits automatically. Uncheck the box if you do not want CTC to
create sequential circuits automatically.
(Figure
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose STS-1. For circuits on the DS3i-N-12 card, choose STS-3c. This sets a port group for
ports 1, 4, 7, and 10 using 3 ports at any given time.
Bidirectional—Leave checked for this circuit (default).
at the node where you will create the circuit.
Step
2.
6-4):
Chapter 6
Create Circuits and VT Tunnels
6-36. Skip this step if you built a
20-8. If not, continue with
Step
3.
August 2005