Table 18-16 Line Threshold Options For The Ds3Xm-6 Card - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 18
DLPs A100 to A199
Table 18-15
Parameter
Service State Identifies the autonomously
AINS Soak
Table 18-16
Table 18-16
Parameter
Port
CV
ES
SES
LOSS
Table 18-17
cards.
March 2007
Line Options for the DS3XM-6 Parameters (continued)
Description
generated state that gives the
overall condition of the port.
Service states appear in the
format: Primary State-Primary
State Qualifier, Secondary State.
Sets the automatic in-service
soak period.
lists the line threshold options for DS3XM-6 cards.
Line Threshold Options for the DS3XM-6 Card
Description
(Display only.) Port number
Coding violations
Errored seconds
Severely errored seconds
Loss of signal seconds
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3XM-6
DLP-A168 Change Line and Threshold Settings for the DS3XM-6 Card
Options
IS-NR—(In-Service and Normal) The port is
fully operational and performing as provisioned.
OOS-AU,AINS—(Out-Of-Service and
Autonomous, Automatic In-Service) The port is
out-of-service, but traffic is carried. Alarm
reporting is suppressed. The ONS node monitors
the ports for an error-free signal. After an
error-free signal is detected, the port stays in
OOS-AU,AINS state for the duration of the soak
period. After the soak period ends, the port
service state changes to IS-NR.
OOS-MA,DSBLD—(Out-of-Service and
Management, Disabled) The port is
out-of-service and unable to carry traffic.
OOS-MA,MT—(Out-of-Service and
Management, Maintenance) The port is
out-of-service for maintenance. Alarm reporting
is suppressed, but traffic is carried and
loopbacks are allowed.
Duration of valid input signal, in hh.mm format,
after which the card becomes in service (IS)
automatically
0 to 48 hours, 15-minute increments
Options
1 to 6
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Cisco ONS 15454 Procedure Guide, R5.0
18-43

Advertisement

Table of Contents
loading

Table of Contents