DLP-A165 Change Line and Threshold Settings for the DS1-14 or DS1N-14 Cards
Table 18-3
Parameter
Service State Identifies the autonomously
AINS Soak
Table 18-4
Table 18-4
Parameter
Port
CV
ES
SES
LOSS
Cisco ONS 15454 Procedure Guide, R5.0
18-30
Line Options for DS1-14 and DS1N-14 Cards (continued)
Description
generated state that gives the
overall condition of the port.
Service states appear in the
format: Primary
State-Primary State Qualifier,
Secondary State.
Sets the automatic in-service
soak period.
describes the values on the Provisioning > Line Thresholds tabs for the DS-1 cards.
Line Thresholds Options for DS1-14 and DS1N-14 Cards
Description
(Display only.) Port number
Coding violations
Errored seconds
Severely errored seconds
Number of one-second intervals
containing one or more loss of signal
(LOS) defects
Options
IS-NR—(In-Service and Normal) The port is fully
operational and performing as provisioned.
OOS-AU,AINS—(Out-Of-Service and
Autonomous, Automatic In-Service) The port is
out-of-service, but traffic is carried. Alarm
reporting is suppressed. The ONS node monitors
the ports for an error-free signal. After an error-free
signal is detected, the port stays in OOS-AU,AINS
state for the duration of the soak period. After the
soak period ends, the port service state changes to
IS-NR.
OOS-MA,DSBLD—(Out-of-Service and
Management, Disabled) The port is out-of-service
and unable to carry traffic.
OOS-MA,MT—(Out-of-Service and Management,
Maintenance) The port is out-of-service for
maintenance. Alarm reporting is suppressed, but
traffic is carried and loopbacks are allowed.
Duration of valid input signal, in hh.mm format,
after which the card becomes in service (IS)
automatically
0 to 48 hours, in 15-minute increments
Options
1 to 14
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Chapter 18
DLPs A100 to A199
March 2007