DLP-A165 Change Line and Threshold Settings for the DS1-14 or DS1N-14 Cards
Table 18-3
Parameter
Service State Identifies the autonomously
AINS Soak
Table 18-4
Table 18-4
Parameter
Port
CV
ES
SES
LOSS
Cisco ONS 15454 Procedure Guide, R5.0
18-30
Line Options for DS1-14 and DS1N-14 Cards (continued)
Description
generated state that gives the
overall condition of the port.
Service states appear in the
format: Primary
State-Primary State Qualifier,
Secondary State.
Sets the automatic in-service
soak period.
describes the values on the Provisioning > Line Thresholds tabs for the DS-1 cards.
Line Thresholds Options for DS1-14 and DS1N-14 Cards
Description
(Display only.) Port number
Coding violations
Errored seconds
Severely errored seconds
Number of one-second intervals
containing one or more loss of signal
(LOS) defects
Options
IS-NR—(In-Service and Normal) The port is fully
•
operational and performing as provisioned.
OOS-AU,AINS—(Out-Of-Service and
•
Autonomous, Automatic In-Service) The port is
out-of-service, but traffic is carried. Alarm
reporting is suppressed. The ONS node monitors
the ports for an error-free signal. After an error-free
signal is detected, the port stays in OOS-AU,AINS
state for the duration of the soak period. After the
soak period ends, the port service state changes to
IS-NR.
OOS-MA,DSBLD—(Out-of-Service and
•
Management, Disabled) The port is out-of-service
and unable to carry traffic.
OOS-MA,MT—(Out-of-Service and Management,
•
Maintenance) The port is out-of-service for
maintenance. Alarm reporting is suppressed, but
traffic is carried and loopbacks are allowed.
Duration of valid input signal, in hh.mm format,
•
after which the card becomes in service (IS)
automatically
0 to 48 hours, in 15-minute increments
•
Options
1 to 14
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click Show Thresholds.
Chapter 18
DLPs A100 to A199
March 2007