NTP-A155 Convert a 1+1 Point-to-Point or a Linear ADM to a Two-Fiber BLSR Manually
d.
In the network graphic, double-click a BLSR span line. If the span line is DCC connected to other BLSR
Step 7
cards that constitute a complete ring, the lines turn blue. If the lines do not form a complete ring,
double-click span lines until a complete ring is formed. Click Next.
The UPSR to BLSR Topology Conversion dialog box appears. The dialog box states that the system is
Step 8
about to force traffic to the shortest path protection paths. Click Next.
Another dialog box appears, stating that the force has been applied to the shortest path protection path.
Step 9
Click Finish.
If the BLSR window appears with the BLSR you created, go to the next step. If a "Cannot Create BLSR"
or "Error While Creating BLSR" message appears:
a.
b.
c.
d.
Note
Verify the following:
Step 10
Stop. You have completed this procedure.
NTP-A155 Convert a 1+1 Point-to-Point or a Linear ADM to a
Two-Fiber BLSR Manually
Purpose
Tools/Equipment
Cisco ONS 15454 Procedure Guide, R5.0
13-8
Complete the
"NTP-A40 Provision BLSR Nodes" procedure on page
completed accurately, then start this procedure again.
Click OK.
In the Create BLSR window, click Excluded Nodes. Review the information explaining why the
BLSR could not be created, then click OK.
Depending on the problem, click Back to start over or click Cancel to cancel the operation.
Complete the
"NTP-A40 Provision BLSR Nodes" procedure on page
completed accurately, then start this procedure again.
Some or all of the following alarms might briefly appear during BLSR setup: E-W MISMATCH,
RING MISMATCH, APSCIMP, APSDFLTK, and BLSROSYNC.
On the network view graphic, a green span line appears between all BLSR nodes.
All E-W MISMATCH, RING MISMATCH, APSCIMP, DFLTK, and BLSROSYNC alarms are
cleared. See the Cisco ONS 15454 Troubleshooting Guide for alarm troubleshooting.
The numbers in parentheses after the node name are the BLSR node IDs assigned by CTC.
Note
Every ONS 15454 in a BLSR is given a unique node ID, 0 through 31. To change it, complete
the
"DLP-A326 Change a BLSR Node ID" task on page
This procedure upgrades a 1+1 point-to-point configuration (two nodes)
or a linear ADM configuration (three or more nodes) to a two-fiber
BLSR manually, that is, without using the in-service topology upgrade
wizard. Use this procedure if the wizard is unavailable or if you need to
back out of the wizard.
None
Chapter 13
Convert Network Configurations
5-10, making sure all steps are
5-10, making sure all steps are
20-16.
December 2004