Create Circuits and VT Tunnels
Step 21
In the Circuits window, verify that the circuits you created appear in the circuits list.
Complete the
Step 22
circuit.
Stop. You have completed this procedure.
NTP-A295 Create a Manually Routed OC-N Circuit
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Step 1
Complete the
If you are already logged in, continue with
Step 2
If you want to assign a name to the tunnel source and destination ports before you create the circuit,
complete the
Step 3
From the View menu, choose Go to Network View.
Click the Circuits tab, then click Create.
Step 4
In the Circuit Creation dialog box, complete the following fields:
Step 5
Click Next.
Step 6
Define circuit attributes:
Step 7
August 2005
If you entered more than 1 in the number of Circuits field and did not choose Auto-ranged, the
Circuit Creation dialog box appears so you can create the remaining circuits. Repeat
Steps
5
through
19
for each additional circuit. After completing the circuits, the Circuits window
appears.
"NTP-A62 Test OC-N Circuits" procedure on page
This procedure creates a manually routed, bidirectional or unidirectional,
OC-N circuit, including STS-1 or concatenated STS-3c, STS-6c, STS-9c,
STS-12c, STS-24c, STS-48c, or STS-192c speeds.
None
NTP-A127 Verify Network Turn Up, page 6-4
As needed
Onsite or remote
Provisioning or higher
"DLP-A60 Log into CTC" task on page 17-66
"DLP-A314 Assign a Name to a Port" task on page
Circuit Type—Choose STS.
Number of Circuits—Enter the number of OC-N circuits you want to create. The default is 1.
Auto-ranged—Applies to automatically routed circuits only. If you entered more than 1 in the
Number of Circuits field, uncheck this box. (The box is unavailable if only one circuit is entered in
Number of Circuits.)
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose the OC-N circuit size. Choices are STS-1, STS-3c, STS-6c, STS-9c, STS-12c,
STS-18c, STS-24c, STS-36c, STS-48c, or STS-192c.
Bidirectional—Leave checked for this circuit (default).
NTP-A295 Create a Manually Routed OC-N Circuit
6-51. Skip this step if you built a test
at the node where you will create the circuit.
Step
2.
20-8. If not, continue with
Cisco ONS 15454 Procedure Guide, R5.0
Step
3.
6-43