Dlp- A441 Install Electrical Cables On The Ubic-H Eias - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 21
DLPs A400 to A499
DLP-A441 Install Electrical Cables on the UBIC-H EIAs
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Note
Cisco recommends that you plan for future slot utilization and fully cable all SCSI connectors that you
will use later.
Step 1
Place a cable connector over the desired connection point on the backplane, making sure the cable runs
toward the outside of the shelf.
Step 2
Carefully push the connector into the backplane until the pin on the cable connector slides into the notch
on the UBIC-H. Make sure the standoffs on the UBIC-H align properly with the notches on the cable.
Step 3
Use the flathead screwdriver to tighten the screws at the top and bottom of the end of cable connector
two to three turns at 8 to 10 lbf-inch (9.2 to 11.5kgf-cm). Alternate between the two screws until both
are tight.
Repeat Steps
Step 4
Figure 21-1
March 2005
This task installs DS-1 and DS-3/EC-1 cables on the Universal Backplane
Interface Connector–Horizontal (UBIC-H) electrical interface assemblies
(EIAs).
3/16-inch flat-head screwdriver
DS-1 and DS-3/EC-1 cables, as needed:
15454-CADS1-H-25
15454-CADS1-H-50
15454-CADS1-H-75
15454-CADS1-H-100
15454-CADS1-H-150
15454-CADS1-H-200
15454-CADS1-H-250
15454-CADS1-H-350
15454-CADS1-H-450
15454-CADS1-H-550
15454-CADS1-H-655
15454-CADS3-SD
15454-CADS3-ID
15454-CADS3-LD
DLP-A399 Install a UBIC-H EIA, page 20-97
As needed
Onsite
None
1
through
3
for each cable you want to install.
shows a UBIC-H with cables installed in all connectors.
DLP-A441 Install Electrical Cables on the UBIC-H EIAs