Dlp- A518 Create A New Or Cloned Alarm Severity Profile - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 22
DLPs A500 to A599
To view card alarm history from node view:
Step 4
a.
b.
Note
c.
d.
Return to your originating procedure (NTP).
Step 5
DLP-A518 Create a New or Cloned Alarm Severity Profile
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
To access the alarm profile editor from network view, click the Provisioning > Alarm Profiles tabs.
Step 1
To access the profile editor from node view, click the Provisioning > Alarm Profiles >
Step 2
Alarm Profile Editor tabs. The node view is shown in
To access the profile editor from a card view, click the following tabs:
Step 3
October 2005
From the View menu, choose Go to Previous View.
Double-click a card on the shelf graphic to open the card-level view.
TCC2/TCC2P cards and cross-connect (XCVT or XC10G) cards do not have a card view.
Click the History > Session tab to view the alarm messages raised during the current session.
Click the History > Card tab to retrieve all available alarm messages for the card and click
Retrieve.
If you check the Alarms check box, the node's alarm history appears. If you check the Events check
box, the node's Not Alarmed and transient event history appears. If you check both check boxes, you
will retrieve node history for both alarms and events.
Note
The ONS 15454 can store up to 640 critical alarm messages, 640 major alarm messages,
640 minor alarm messages, and 640 condition messages. When any of these limits is
reached, the ONS 15454 discards the oldest events in that category.
Raised and cleared alarm messages (and events, if selected) appear.
This task creates a custom severity profile or clones and modifies the
default severity profile.
None
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
If the card is an FC_MR-4, E-Series Ethernet, G-Series Ethernet, OC-N, or electrical (DS-1, DS-1N,
DS-3, DS-3N, DS3-12E, DS3-12E-N, DS3i, DS3i-N, DS3XM, or EC-1) card, click the
Provisioning > Alarm Profiles > Alarm Profile Editor tabs.
If the card is an ML-Series Ethernet (traffic) card, click the Provisioning > Ether Alarming >
Alarm Behavior tabs to apply the profile to the front physical ports, or the Provisioning >
POS Alarming > Alarm Behavior tabs to apply the profile to the packet-over-SONET (POS) ports.
DLP-A518 Create a New or Cloned Alarm Severity Profile
Figure 7-2 on page
7-5.
Cisco ONS 15454 Procedure Guide, R5.0
22-9