DLP-A27 Install Coaxial Cable with SMB Connectors
Place the SMB cable connector over the desired connection point on the backplane
Step 1
Figure 17-16
Gently push the connector until it clicks into place.
Step 2
Tie wrap or lace the cables to the EIA according to Telcordia standards (GR-1275-CORE) or local site
Step 3
practice.
Route the cables to the nearest side of the shelf assembly into rack runs according to local site practice.
Step 4
IMetallic interfaces for connection to outside plant lines (such as T1/E1/T3/E3 etc.) must be connected
Warning
through a registered or approved device such as CSU/DSU or NT1. Statement 290
Label the transmit, receive, working, and protect cables at each end of the connection to avoid confusion
Step 5
with cables that are similar in appearance.
Return to your originating procedure (NTP).
Step 6
Cisco ONS 15454 Procedure Guide, R5.0
17-34
Installing Coaxial Cable with SMB Connectors
Chapter 17
DLPs A1 to A99
(Figure
17-16).