DLP-A71 Create a 1:1 Protection Group
Internal timing is Stratum 3 and not intended for permanent use. All ONS 15454s should be timed to a
Caution
Stratum 2 or better primary reference source.
In node view, click the Provisioning > Timing > General tabs.
Step 1
In the General Timing area, enter the following:
Step 2
Step 3
In the Reference Lists area, enter the following information:
Click the Provisioning > Timing > BITS Facilities tabs.
Step 4
In the BITS Facilities area, change the BITS In State and BITS Out State to OOS. Disregard the other
Step 5
BITS Facilities settings; they are not relevant to internal timing.
Step 6
Click Apply.
Step 7
Return to your originating procedure (NTP).
DLP-A71 Create a 1:1 Protection Group
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Verify that the cards required for 1:1 protection are installed according to requirements specified in
Step 1
Table 4-1 on page
In node view, click the Provisioning > Protection tabs.
Step 2
Step 3
Click Create.
Cisco ONS 15454 Procedure Guide, R5.0
17-78
Timing Mode—Set to External.
SSM Message Set—Set to Generation 1.
Quality of RES—Does not apply to internal timing.
Revertive—Does not apply to internal timing.
Revertive Time—Does not apply to internal timing.
NE Reference
Ref 1—Set to Internal Clock.
Ref 2—Set to Internal Clock.
Ref 3—Set to Internal Clock.
BITS-1 Out/BITS-2 Out—Set to None.
This task creates a 1:1 electrical card protection group.
Redundant DS-1, DS-3, EC-1, or DS3XM cards should be installed in the
shelf, or the ONS 15454 slots must be provisioned for two of these cards.
DLP-A60 Log into CTC, page 17-66
As needed
Onsite or remote
Provisioning or higher
4-10.
Chapter 17
DLPs A1 to A99
March 2005