Cisco ONS 15454 Series Procedure Manual page 148

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

NTP-A177 Path Protection Acceptance Test
NTP-A177 Path Protection Acceptance Test
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
This procedure might be service affecting if performed on a node carrying traffic.
Caution
Complete the
Step 1
protection you are testing. If you are already logged in, continue with Step 2.
From the View menu, choose Go to Network View.
Step 2
Click the Alarms tab.
Step 3
a.
b.
c.
Click the Conditions tab.
Step 4
a.
b.
Step 5
On the network map, double-click the node that you logged into in Step 1.
Step 6
Create a test circuit from that node to the next adjacent path protection node.
Configure the test set for the test circuit type you created:
Step 7
Cisco ONS 15454 Procedure Guide, R5.0
5-22
This procedure tests a path protection.
Test set and cables appropriate to the test circuit you will create.
NTP-A44 Provision Path Protection Nodes, page 5-20
As needed
Onsite
Provisioning and higher
"DLP-A60 Log into CTC" task on page 17-66
Verify that the alarm filter is not on. See the
page 19-17
as necessary.
Verify that no unexplained alarms appear on the network. If unexplained alarms appear, resolve
them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide if necessary.
Complete the
"DLP-A516 Export CTC Data" task on page 22-6
Verify that no unexplained conditions appear on the network. If unexplained conditions appear,
resolve them before continuing. Refer to the Cisco ONS 15454 Troubleshooting Guide if necessary.
Complete the
"DLP-A516 Export CTC Data" task on page 22-6
information.
For DS-1 circuits, complete the
procedure on page
6-6. When you set the circuit state, choose IS and check the Apply to drop ports
check box.
For DS-3 circuits, complete the
procedure on page
6-18. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
For OC-N circuits, complete the
procedure on page
6-38. When you set the circuit state, choose IS and check the Apply to drop
ports check box.
DS-1—If you are testing a DS-1 that is not multiplexed, you must have a DSX-1 panel or a direct
DS-1 interface into the ONS 15454. Set the test set for DS-1. For information about configuring
your test set, consult your test set user guide.
at one of the ONS 15454s on the path
"DLP-A227 Disable Alarm Filtering" task on
"NTP-A181 Create an Automatically Routed DS-1 Circuit"
"NTP-A184 Create an Automatically Routed DS-3 Circuit"
"NTP-A257 Create an Automatically Routed OC-N Circuit"
Chapter 5
Turn Up Network
to export the alarm information.
to export the conditions
December 2004

Advertisement

Table of Contents
loading

Table of Contents