Ntp- A146 Test E-Series Circuits - Cisco ONS 15454 Series Procedure Manual

Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 6
Create Circuits and VT Tunnels
Complete the
Step 22
Complete the
Step 23
page
19-14.
From the View menu, choose Go to Home View.
Step 24
Click the Circuits tab.
Step 25
Highlight the circuit and click Edit.
Step 26
The Edit Circuit dialog box appears.
Step 27
In the Edit Circuit dialog box, click the Drops tab. A list of existing drops appears.
Step 28
Click Create.
In the Define New Drop dialog box, define the new drop:
Step 29
Node—Choose the target node for the circuit drop.
a.
Slot—Choose the OC-N card that links the ONS 15454 to the non-ONS 15454 equipment.
b.
Port, STS—Choose the port and/or STS from the Port and STS drop-down lists.
c.
The routing preferences for the new drop match those of the original circuit. However, if the
d.
following options are available, you can modify them:
If you want to change the circuit state, choose the circuit state from the Target Circuit Admin State
e.
drop-down list. The state chosen applies to the entire circuit.
Check Apply to drop ports if you want to apply the state chosen in the Target Circuit Admin State
f.
to the circuit source and destination drops. For the requirements necessary to apply a service state
to drop ports, refer to the Cisco ONS 15454 Reference Manual.
Click Finish. The new drop appears in the Drops list.
g.
Confirm the circuit information that appears in the Edit Circuit dialog box and click Close.
Step 30
Repeat Steps
Step 31
The first and second Ethernet manual cross-connect endpoints will be bridged by the OC-N STS
cross-connect circuit.
Note
If a CARLOSS alarm repeatedly appears and clears on an Ethernet manual cross-connect, the two
Caution
Ethernet circuits might have a circuit-size mismatch. For example, a circuit size of STS-3c was
configured on the first ONS 15454 and circuit size of STS-12c was configured on the second
ONS 15454. Refer to the Cisco ONS 15454 Troubleshooting Guide if the alarm persists.
Step 32
Complete the
Stop. You have completed this procedure.
August 2005
"DLP-A220 Provision E-Series Ethernet Ports" task on page
"DLP-A221 Provision E-Series Ethernet Ports for VLAN Membership" task on
If the original circuit was routed on a protected path protection path, you can change the nodal
diversity options: Nodal Diversity Required, Nodal Diversity Desired, or Link Diversity Only.
If the original circuit was not routed on a protected path, the Protection Channel Access option
is available.
2
through
30
at the second Ethernet manual cross-connect endpoint.
The appropriate STS circuit must exist in the non-ONS equipment to connect the two Ethernet
manual cross-connect endpoints.
"NTP-A146 Test E-Series Circuits" procedure on page
NTP-A145 Create an E-Series Multicard EtherSwitch Manual Cross-Connect
Cisco ONS 15454 Procedure Guide, R5.0
19-13.